This rugged unit heater works well in industrial settings. Install it in factories, warehouses, garages, stairwells, power stations or mechanical rooms. Its powerful output capacity even makes it suitable for heating your loading dock or other indoor/outdoor transition spaces.
QMARK® Unit Heater, MUH Series, 10.2 Btu/hr, 480 V, 3.6 A, 350 cfm, 1/100 hp, 3 kW, 3 ph, 9 in Mounting Height, Beige, 40 to 90 deg F, 16 in H x 14 in W x 7-1/2 in D
| BTU Rating |
: |
10.2 Btu/hr |
| BTU/HR |
: |
10,200 btu/hr |
| CFM Rating |
: |
350 cfm |
| CFM |
: |
350 CFM |
| Color |
: |
Beige |
| Control Volts |
: |
24 V |
| Dimensions |
: |
16 in H x 14 in W x 7-1/2 in D |
| FPM |
: |
800 FPM |
| Finish |
: |
Polyester Powder-Coated |
| HP Rating |
: |
1/100 hp |
| Horizontal Throw |
: |
12 ft |
| KW |
: |
3.0 kW |
| Model |
: |
MUH-0341 |
| Motor HP |
: |
1/100 hp |
| Mounting Height |
: |
9 in |
| Phase |
: |
3 ph |
| Power Rating |
: |
3 kW |
| Series |
: |
MUH Series |
| Temperature Rating |
: |
40 to 90 deg F |
| Voltage Rating |
: |
480 V |
| Voltage |
: |
480 V |
| Weight |
: |
27 lbs. |
| Wire Size |
: |
14 AWG |
| ��T (��F) |
: |
27 ��F |
- Wide range of optional control kits are field-installable, increasing the unit's adaptability to specification market
- Heavy gauge die-formed steel housing, two-toned, smartly-styled with stainless steel louvers
- Advanced pull through air flow design draws air across heating element for even air distribution and cooler element operation
- Specially designed venturi outlet to meet required additional air throw in vertical position
- Branch circuit fusing, when required
- Completely enclosed fan motor
- Two-speed fan selector switch (25 to 50 kW models)
- Aluminum finned, copper clad steel sheath heating element extends life due to cooler sheath temperature and faster heat dissipation
- Automatic reset linear thermal cutout, capillary-type, provides protection over entire length of element areas
- No piping flues, valves or traps needed for installation
- Individually adjustable louvers to direct air flow
- Ruggedly built, yet lighter weight for easier installation, no piping flutes, valves or traps
- 8 in horizontal, 9 in vertical maximum effective mounting height
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/QMARK_MUH_0341_Instruction_Installation_Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/QMARK_MUH_0341_Specification_Sheet.pdf
-
Submittal
https://assets.unilogcorp.com/267/ITEM/DOC/QMARK_MUH_0341_Submittal.pdf